ULTRAN® - MaxiFlex is a CrossFlow system, which was
developed for the laboratory/pilot scale up to smaller
productions in the biotechnology and pharmaceutical market. The
design meets the requirements of GMP and makes a simple
validation possible.
The system can be operated with the stainless steel filter
holders ULTRAN - FH - Slice or - Pilot. The exchange can be
managed simply and quickly with minimum effort. Membrane areas
between 0.1 m˛ and 2 m˛ can therefore be realized by the use of
our membrane cassettes ULTRAN - Slice and Pilot, depending on
application.
The pipe pressure regulators included in the basic version at
the inlet, retentate and filtrate allow precise adjustment of
the process conditions. The digital flowmeter allows easy
observation and adjustment of the output of the
4-piston-membrane-pump. The 10 litre reservoir has two windows
to check the filling level.
Documentation of the process conditions (pressure, flow rate,
pH value, conductivity and temperature) is possible with the
digital version. Use of our unique heat exchanger systems allows
temperature control of the feed solution.
ULTRAN® - Heat Exchanger cassettes in both Slice and Pilot
format and the appropriate separating plates are available as
accessories. Special plant configurations can be produced on
request.
Applications
- Protein concentration
- Continuous buffer exchange
- Concentration and buffer exchange of column
chromatography fractions
- Cell harvesting / washing
- Colloidal suspension concentration / diafiltration
- Virus concentration
| Number of applicable
cassettes |
| Cassette geometry |
Channel Geometry |
without |
with |
| |
|
Heat Exchanger |
Heat Exchanger |
| ULTRAN® Slice |
Screen Channel |
5 |
5 |
| ULTRAN® Slice |
Open Channel |
5 |
5 |
| ULTRAN® Pilot |
Screen Channel |
4 |
3 |
| ULTRAN® Pilot |
Open Channel |
2 |
1 |
| ULTRAN - MaxiFlex
System |
| Dimensions (W x L x H) |
86 x 58 x 95 cm |
| Weight |
|
| - with ULTRAN - FH - Slice |
c. 80 kg |
| - with ULTRAN - FH - Pilot |
c. 100 kg |
| Material |
|
| - Stainless Steel Filter Holder |
1.4539 (Ra < 0.4 µm) |
| - other components |
1.4435 (Ra < 0.4 µm) |
| Pump |
4-piston-membrane-pump |
| - output |
max. 1000 L/h |
| - power supply capacity: |
c. 550 W |
| - electrical connectors: |
analogous to the country of
operation |
| Reservoir with 2 windows |
|
| - volume |
c. 10 Litre |
| - connectors |
|
| - at conical bottom: |
1 x ľ" |
| - at cover plate: |
1 x 1 ˝" |
| |
1 x ľ" with downcomers for
retentate (long) |
| |
3 x ˝" with downcomers (short) |
| Fittings |
3 x Pipe presure regulator
(Inlet, etentate, filtrate) |
| |
1 x magnetic-inductive
flowmeter |
| |
1 x T-membrane-sampling valve |
| |
3 x ľ" Membrane valve |
| |
1 x ˝" Membrane valve |
| |
2 x aseptic sampling valvel |
| Ordering Information
- ULTRAN - MaxiFlex System |
| |
Catalogue Number |
| ULTRAN - MaxiFlex 100 S (Slice) |
10 478 920 |
| ULTRAN - MaxiFlex 100 P (Pilot) |
10 478 930 |
| ULTRAN - MaxiFlex 100 SD (Slice
Digital) |
10 478 925 |
| ULTRAN - MaxiFlex 100 PD (Pilot
Digital) |
10 478 935 |
| Torque wrench ULTRAN - FH -
Slice |
10 478 327 |
| Torque wrench ULTRAN - FH -
Pilot |
10 478 324 |
| Heat Exchanger-Separating plate
Slice |
10 478 359 |
| Heat Exchanger-Separating plate
Pilot |
10 478 336 |
| Heat Exchanger-Cassette Slice |
10 478 328 |
| Heat Exchanger-Cassette Pilot |
10 478 330 |
| Ordering Information
- ULTRAN - PES Membrane Cassettes |
| ULTRAN - Slice |
| Cut off / Pore size |
Screen Channel |
Open Channel |
| 5 kD |
10 478 610 |
– |
| 10 kD |
10 478 620 |
– |
| 30 kD |
10 478 630 |
– |
| 50 kD |
10 478 640 |
– |
| 100 kD |
10 478 650 |
– |
| 300 kD |
– |
10 478 665 |
| 500 kD |
– |
10 478 675 |
| 0.20 µm |
– |
10 478 685 |
| 0.45 µm |
– |
10 478 695 |
| ULTRAN- Pilot |
| Cut off / Pore size |
Screen Channel |
Open Channel |
| 5 kD |
10 478 710 |
– |
| 10 kD |
10 478 720 |
– |
| 30 kD |
10 478 730 |
– |
| 50 kD |
10 478 740 |
– |
| 100 kD |
10 478 750 |
– |
| 300 kD |
– |
10 478 765 |
| 500 kD |
– |
10 478 775 |
| 0.20 µm |
– |
10 478 785 |
| 0.45 µm |
– |
10 478 795 |
Additional membrane areas on request.
|