Membrane filtration

The technical requirements for membrane filters used in microbiological quality control are subject to strict national and international standards.

 

At the same time the requirements of the market are continually changing as a result of the introduction of new products, such as soft drinks, alcoholic mixed drinks or pharmaceuticals.

Whatman offers a wide and versatile range of membrane filter products with a very high level of consistent quality

Product Navigation

Membrane-Butler

MicroPlus_and_ME_membranes

 

 

 

Membrane filtration
> Removing a sterile membrane from Butler E.
Membrane-Butler
Membrane filter dispenser for microbiological control
Membrane filters for microbiological checks must be carefully handled to ensure that they remain sterile and that quantitative results are being obtained.
 

 

Membrane filtration
> Manual Dispenser for single sterile membranes

The Membrane Butler offers optimal handling for all MicroPlus and ME membrane filters with the type name "STL". The dispenser box is placed in the Membrane Butler, the sterile packing is inserted into the roller system and the system is ready. With each turn (Manual Butler) or by pressing the push button (Butler E) a membrane filter is removed from its sterile packing and can easily be removed with forceps.
 

Features and Benefits
 

  • High reliability
  • Simple handling with foot switch and stepper motor (applies only to Butler E)
  • Cross-contamination risks are minimised
  • Membrane dispensed rapidly
  • Ideal for use on sterile benches
  • Compact dimensions for portable use

 

Membrane-Butler Workflow
 

 

Membrane filtration

1. Insert the membrane package in the support.
 

 

Membrane filtration

2. Guide the sterile packing through the transportation rollers so that two sections protrude.
 

 

Membrane filtration

3. Reinsert the guidance clip.
 

 

Membrane filtration

4. By pressing the push button the signal for the feed operation is started and the membrane can be removed.
 

 

Ordering Information - Membrane-Butler
Catalogue Number Description Use Quantity/Pack
10 477 100 Membrane-Butler Manual dispenser 1
10 477 110 Membrane-Butler E Electrical dispenser 1
10 477 112 Butler Tower For two Butler E 1
10 477 113 Foot pedal For Butler E automatic dispensing 1
 

 

MicroPlus and ME membranes
Membranes for microbiological control
The absence of microbial contamination in beverages, cosmetics and pharmaceuticals is a very important factor in quality control. It protects the consumer.

 

In these products the microorganism counts are very low and are therefore determined quantitatively via enrichment methods. Production processes are continuously monitored at their critical points (tanks, pipelines, filling units), as are the finished products. The membrane filter method is the optimal analytical method for doing this.

Method

The liquid is filtered through a membrane. The microorganisms collect on the membrane surface. The filter is incubated on a nutrient medium and the individual colonies can then be evaluated. The method is also suitable for large sample volumes and low microorganism counts.

Reliability

Our quality control and product design offer you the decisive advantages. The membrane filters are strictly controlled and fulfil or exceed the requirements according to DIN, ASTM, and HIMA.

Test parameters

The following parameters of all membranes used for microbiological quality control are systematically tested in order to ensure the same high quality from batch to batch: bubble pressure for bacterial growth; flow rate for bacterial retention; thickness for porosity toxicology.

MicroPlus Membranes

Features and Benefits

  • Special membrane filters made from cellulose nitrate developed for microbiological quality control
  • High mechanical strength
  • Double flow rate
  • Ideal for samples with a high particle content and viscous samples
  • Sterile, individually packed
  • Pore size 0.45 µm
  • All membrane filters have a high-contrast grid (3.1 mm)
  • Type STL in dispenser boxes with 100 numbered membrane filters for easy removal and safe handling with the Membrane-Butler (supplied in 4 boxes each with 100 membrane filters)

 

ME Membranes

Features and Benefits

  • Economical
  • Specially for aqueous solutions
  • Hydrophilic
  • For use up to 125º C
  • Autoclavable up to 121º C

 

Ordering Information - MicroPlus
Catalogue Number Description Colour / Grid Diameter (mm) Quantity/Pack
10 407 112 MicroPlus-21 STL white / black 47 4 x 100
10 407 114 MicroPlus-21 STL white / black 50 4 x 100
10 407 713 MicroPlus-21 ST white / black 47 1 x 100
10 407 714 MicroPlus-21 ST white / black 50 1 x 100
10 407 132 MicroPlus-31 STL black / white 47 4 x 100
10 407 134 MicroPlus-31 STL black / white 50 4 x 100
10 407 734 MicroPlus-31 ST black / white 50 1 x 100
10 407 170 MicroPlus-41 STL green / black 47 4 x 100
10 407 172 MicroPlus-41 STL green / black 50 4 x 100
ME (Mixed cellulose ester) 
10 407 312 ME 25/21 STL white / black 47 4 x 100
10 407 314 ME 25/21 STL white / black 50 4 x 100
10 406 870 ME 25/21 ST white / gridded 47 1 x 100
10 406 872 ME 25/21 ST white / gridded 50 1 x 100
10 407 332 ME 25/31 STL black / white 47 4 x 100
10 407 334 ME 25/31 STL black / white 50 4 x 100
10 407 370 ME 25/41 STL green / black 47 4 x 100
10 407 372 ME 25/41 STL green / black 50 4 x 100
10 409 470 ME 25/41 ST green / gridded 47 1 x 100
10 409 472 ME 25/41 ST green / gridded 50 1 x 100

STL - for use with our Membrane-Butler
ST - single sterile packed  

 

 

For more information :: Bioxys and Gentaur BVBA :: Av. de l'Armée 68 B4 :: BE-1040 BELGIUM

Email: info@gentaur.com
 

International 

+32 (0) 16 58 90 45

+32 (0) 16 50 90 45

France

01 43 25 01 50

01 43 25 01 60

Italy

02 36 00 65 93

02 36 00 65 94

Germany

0241 6085 13140

0241 6085 33033

Send mail to webmaster with questions or comments about this web site.
Copyright © 2005 Gentaur BVBA
Last modified: feb-07