Membrane accessories
|
Apparatus pressure
filtration
Batch filtration – Selectron®
Whatman offers a line of pressure filtration apparatus for
clarification and filtration of aqueous liquids and gases.
Pressure filtration apparatus without sample funnels are for
in-line use and are suitable for larger volumes of several
liters. Apparatus with sample funnels are suitable for the batch
filtration of volumes above 20 mL.
Liquid and gas filtration are possible; they can also be used
for the sterile filtration of sera or the clarification of
difficult-to-filter media, very viscous liquids in particular.
Membrane, paper or glass fibre filters can be used. Cleaning
and changing filters are carried out with only a few actions.
All units are provided with pressure-resistant filter supports.
High-quality silicone or PTFE O-rings are used to seal the
systems. For safety reasons please take care that the seals are
not damaged. In addition to the stainless steel apparatus we
offer PTFE versions for aggressive media.
| Application |
| |
Apparatus |
| Clarification of small volume
difficult-to-filter liquids and sterile filtration of
liquids and gases |
MD 050 |
| In-line sterilization of
biological liquids, ophthalmic agents, etc. |
MD 142/6 |
| Filtration of aggressive
liquids which must not come into contact with metals |
MD 142/6 |
| For larger volumes; in-line
filtration or with sample funnel |
MD 142/7 |
| Product Selection -
Batch Filtration |
| Type |
Material |
Seals |
Max.pressure* (bar) |
Max. temperature (°C) |
Filter diameter (mm) |
Prefilter diameter (mm) |
| MD 050 |
Stainless steel |
Silicone/PTFE |
10/4 |
200 |
50 |
43 |
| MD 142/5 |
Stainless steel |
Silicone/PTFE |
10/4 |
200 |
142 |
134 |
| MD 142/6 |
Stainless steel |
Silicone/PTFE |
10/4 |
200 |
142 |
134 |
| MD 142/7 |
PTFE |
PTFE |
3.5 |
200 |
142 |
134 |
| * with silicone O-ring/PTFE O-ring |
| Ordering Information
- Batch Filtration |
| Type |
Sample funnel (mL) |
Height x Diameter (mm) |
Catalogue Number |
| Stainless Steel |
| MD 050/0 |
100 |
100 x 70 |
10 450 000 |
| MD 050/4* |
200 |
230 x 70 |
10 450 450 |
| MD 142/5 |
without |
100 x 180 |
10 451 410 |
| MD 142/5/3 |
2200 |
545 x 200 |
10 451 610 |
| MD 142/6 (GMP) |
without |
155 x 170 |
10 452 010 |
| MD 142/6/3 (GMP)** |
2200 |
570 x 220 |
10 452 600 |
| PTFE |
| MD 142/7 |
without |
180 x 200 |
10 451 700 |
| MD 142/7/3 |
1500 |
470 x 200 |
10 451 710 |
| * with aeration valve and quick
connections |
| ** 1" tri-clover connections at inlet
and outlet |
Sampling and
In-line Use – Selectron
The filtration apparatus are suitable for repeated use with
membrane, paper or glass fibre circle filters.
They are particularly easy to take apart for cleaning or
changing filters. All units are fitted with a pressure-resistant
filter support. High quality silicone or PTFE seals ensure that
the units do not leak. For safety reasons please take care that
these sealing elements are not damaged. The filtration apparatus
is made of stainless steel or polysulfone.
| Applications -
Sampling and In-line Use |
| |
Series Type |
| In-line clarification and
sterile filtration of liquids and gases for small
volumes of gas pressure and fuel lines |
ML 050/0 |
| For microbiological checks and
provision of particle-free sterile water; for
peristaltic pumps and gas sterilisation |
FP 050/1 |
| Product Selection -
Sampling and In-line Use |
| Series |
Material |
Seals |
Max. pressure (bar) |
Max. temperature (°C) |
| ML |
Stainless steel |
Silicone O-ring/PTFE flat seal |
10 |
200 |
| FP |
Polysulfone |
Silicone O-ring |
7 |
180 |
| Ordering Information
- Sampling and In-Line Apparatus |
| Type |
Filter size (mm) |
Prefilter (mm) |
Height x Diameter (mm) |
Catalogue Number |
Quantity/ Pack |
| Stainless steel |
| ML 050/0 |
50 |
40 |
160 x 60 |
10 464 100 |
1 |
| Polysulfone |
| FP 050/1 |
50 |
42 |
95 x 65 |
10 461 300 |
1 |
|
|
| |
Apparatus
vacuum filtration
Diaphragm Pumps
Whatman diaphragm pumps are equipped with a condenser; together with
their construction are to a large extent inert for vacuum/pressure
filtration.
Quiet running. Oil-free. Complete and ready for use. With carrying
handle, rubber feet, 1.5 m connection cable with grounded plug, toggle
switch, fine regulation valve, pressure gauge(s), vacuum meter, tubing
nozzle and connection piece for tubing connections with R 3/8” thread.
| Product Specifications -
Diaphragm pump - VP003 |
| Pumping capacity |
3.6 m3/h |
| Ultimate pressure* (vacuum) |
< 100 mbar |
| Max. pressure** (compression) |
4 bar |
| Weight |
11 dg |
| Dimensions (L x B x H) (mm) |
266 x 235 x 174 |
| Max. ambient temperature: |
40°C |
| Motor rating: |
0.18 Kw |
| Nominal speed (50/60 Hz): |
1500/1800 min-1 |
| Mains supply: |
230 V, 50 – 60 Hz |
| Protection code: |
IP 54 |
| Ordering Information -
Apparatus Pressure Filtration |
| Diaphragm Pump |
Catalogue Number |
Quantity/Pack |
| VP 003 |
10 470 300 |
1 |
| For GMP pressure
filtration apparatus** |
| |
Connection |
For |
Catalogue Number |
Quantity/Pack |
| MD 142/2/17 |
Nozzle 25 - 28 mm o.d. |
Pressure tubing |
10 453 207 |
1 |
| ** apparatus-side connection to flange for
tri-clover with clamp, supplied complete with seal rings |
| Fabric-reinforced tubing |
| |
Max. pressure (bar) |
Connections |
I.D. (mm) |
Length (m) |
Catalogue Number |
Quantity/Pack |
| SV 003 a |
10 |
R 3/8"/SVK |
6 |
1.5 |
10 471 100 |
1 |
| SV 003 c |
10 |
SVK/R 3/8" |
6 |
1.5 |
10 471 101 |
1 |
MV Series - Selectron®
All MV series vacuum filtration devices are made of stainless steel and
are chemically resistant to most aqueous and organic solutions.
| Product Specifications - MV
050 Series |
| Filter size |
47/ 50 mm |
| Filter area |
12.5 cm2 |
| Prefilter |
40 mm diameter |
| Vacuum connection |
Rubber stopper |
| Filter support |
Sieve (frit as accessory) |
| Materials |
| Upper and lower parts |
Stainless steel 1.4301 |
| Cover |
Stainless steel 1.4301 |
| Frit |
Stainless steel 1.4571 |
| Sieve |
Stainless steel 1 4301 |
| Seals |
PTFE and silicone |
| Clamps |
Aluminium |
| The MV series can be used up to 200 ºC, can be
autoclaved and sterilised by dry heat at up to 180 ºC. |
| Ordering Information - MV
Series |
| Type |
Funnel volume (mL) |
Height x diameter (mm) |
Catalogue Number |
| MV 050/2 |
100 |
230 x 60 |
10 440 200 |
| MV 050/0 |
500 |
320 x 110 |
10 440 000 |
| MV 050A/0* |
500 |
320 x 110 |
10 440 020 |
| * With rapid closure clamp |
| Accessories |
| Type |
Description |
Catalogue Number |
| ML 050/0/03 |
Steel frit with ring |
10 464 103 |
Multiple Vacuum Filtration - Selectron® AS Series
The stainless steel manifold for 3 or 6 filtration units is fitted with
glass or stainless steel units. The apparatus can be autoclaved and
sterilized by dry heat at up to 180°C. Suitable for vacuum operation
only. If flushing tubes are used do not exceed 1.3 bar (300 mbar
over-pressure).
Serial filtration with a common drainage outlet can be carried out
easily and rapidly. Each unit can be operated by a separate stopcock.
Each unit can be switched and vented individually. Vacuum filtration
apparatus is easy to disassemble. Each single piece is also available
separately and is easily exchanged.
- Three sizes with 250 mL (glass), 100 mL or 500
mL (stainless steel) units
- Two PVC manifolds with three or six stopcocks
and lower parts for individual choice of filter units
- Vacuum connection via tubing nozzle 13 mm O.D.
- Scope of supply: multiple filtration
apparatus complete and ready for use, but without filters and
prefilters
| Ordering Information -
Multiple Vaccum Filtration |
| Type |
Funnel Capacity (mL) |
Units From Series |
Filter Support |
Catalogue Number |
Quantity/ Pack |
| Three-place filtration
apparatus |
| AS 300/5 |
100 |
MV, stainless steel |
Sieve |
10 445 850 |
1 |
| AS 300/1 |
250 |
GV, glass |
Glass frit |
10 445 810 |
1 |
| AS 300/2 |
250 |
GV, glass |
Sieve |
10 445 820 |
1 |
| AS 300/3 |
500 |
MV, stainless steel |
Sieve |
10 445 830 |
1 |
| AS 310/3 * |
500 |
MV, stainless steel |
Sieve |
10 445 835 |
1 |
| Six-place filtration
apparatus |
| AS 600/5 |
100 |
MV, stainless steel |
Sieve |
10 444 850 |
1 |
| AS 600/1 |
250 |
GV, glass |
Glass frit |
10 444 810 |
1 |
| AS 600/2 |
250 |
GV, glass |
Sieve |
10 444 820 |
1 |
| AS 600/3 |
500 |
MV, stainless steel |
Sieve |
10 444 830 |
1 |
| AS 610/3 * |
500 |
MV, stainless steel |
Sieve |
10 444 835 |
1 |
| * With rapid closure clamp |
| Accessories |
| Type |
Description |
Dimensions (Lx B x H) (mm) |
Catalogue Number |
| AS 003/0 |
Apparatus holder |
500 x 270 x200 |
10 445 700 |
| AS 003/0/05 |
Suction manifold |
— |
10 445 708 |
Glass Apparatus – Selectron GV Series
The GV series of vacuum apparatus are made from glass making them
resistant to acids and bases.
| Product Specifications - GV
Series |
| Upper and lower parts |
Borosilicate glass |
| Cover |
Silicone |
| Flask |
Borosilicate glass |
| Frit |
Glass 2D |
| Sieve |
Stainless steel, teflonized |
| Seals |
PTFE and silicone |
| Clamps |
Aluminum and stainless steel |
| Tubing connection |
POM, RD14 thread |
| The GV series can be used up to 200 ºC, can be
autoclaved and sterilised by dry heat at up to 180 ºC. |
| Product Selection - GV Series |
| Type |
Funnel capacity (mL) |
Filter size (mm) |
Filter area (cm2) |
Prefilter (mm) |
Height x diameter* (mm) |
| GV 025 |
60 |
24/25 |
3.1 |
20 |
210/335 x 45 |
| GV 050 |
250 |
47/50 |
12.5 |
40 |
225/450 x 80 |
| GV 100 |
500 |
100 |
70 |
80 |
225 x 90 |
| * Height with/without Erlenmeyer flask; diameter
without clamp and tubing connection |
| Ordering Information - GV
Series |
| Type |
Filter Support |
Vacuum Connection |
Catalogue Number |
| GV 025 series |
| GV 025/0 |
Glass frit |
Rubber stopper |
10 441 000 |
| GV 025/1 |
Sieve |
Rubber stopper |
10 441 100 |
| GV 025/2 |
Glass frit |
TC**, EF*** 250 mL (NS 29) |
10 441 200 |
| GV 050* series |
| GV 050/0 |
Glass frit |
Rubber stopper |
10 442 000 |
| GV 050/1 |
Sieve |
Rubber stopper |
10 442 100 |
| GV 050/2 |
Glass frit |
TC**, EF*** 1000 mL (NS45) |
10 442 200 |
| GV 050A/2 |
Glass frit |
TC**, EF*** 1000 mL (NS45) |
10 442 220 |
| GV 050/3 |
Sieve |
TC**, EF*** 1000 mL (NS45) |
10 442 300 |
| GV 100 series |
| GV 100/0 |
Glass frit |
Rubber stopper |
10 443 000 |
| GV 100/1 |
Sieve |
Rubber stopper |
10 443 100 |
| * Silicone cap and venting nozzle included in
scope of supply
|
| ** TC = tubing connection |
| *** EF = Erlenmeyer flask |
|
|
Membrane holders and
accessories
Whatman offers a choice of holders for use with membrane
filters.
 |
 |
 |
|
> Membrane Filter Holders |
 |
Vacuum Type Glass Holders
Produced from borosilicate glass and available with a choice
of support screen. Suitable for aqueous and organic solvent
filtration. The funnel seal ensures that the sample does not
bypass the membrane and that particulates are retained on the
surface of the membrane.
The sintered glass support is recommended for filtration and
biological analysis. The 304 stainless steel support screen is
suitable for use with proteinaceous solutions.
Syringe Filter Type Membrane Filter Holders
Available in stainless steel and polypropylene with luer
fittings for use with a standard syringe. The holders are
designed for the quick and easy clarification, sterilization and
removal of particulates from small volume samples, typically for
HPLC applications. The holders contain PTFE gaskets and O-rings
and allow the membrane to be autoclaved in place without the
filter sticking to the holder.
Hardware/Replacement Parts
Whatman offers both stoppers and glass reservoirs.
Polyester Drain Discs
For use with membrane hardware where extra support is needed
for improved flow rate and throughput. The Polyester Drain Disc
is binder-free and has a thickness of 100 µm. It provides a flat
surface to eliminate filter tearing or rupturing. It is also
used as a separator between membrane layers in serial stack
filtration applications. This chemically inert support disc is
available in a variety of diameters for use in a range of
devices.
Applications
General laboratory microfiltration
Quality control and sterility testing
Removal of particulates from HPLC solvents
Tissue culture media filtration
| Typical Data |
| Filter Diameter (mm) |
Membrane Holder |
| Membrane |
Filter Systems—Glass |
Reservoir Volume (mL) |
Filter Surface Area (cm2) |
Prefilter Diameter (mm) |
| 25 |
FG 25 |
25 |
2.1 |
16 |
| 25 |
FG 25R |
50 |
2.1 |
13 |
| 25 |
FG 25S |
25 |
2.1 |
16 |
| 47 |
FG 47 |
300 |
9.6 |
35 |
| 47 |
FG 47S |
300 |
9.6 |
35 |
| 90 |
FG 90 |
1000 |
38.5 |
70 |
| Ordering Information
- Membrane Holders and Accessories |
| Diameter (mm) |
Description |
Catalogue Number |
Quantity/Pack |
| Membrane Filter
Holders |
| 25 |
Glass Support 50 mL–FG 25R
Sintered Glass |
1960-032 |
1 |
| 25 |
Glass Support 25 mL–FG 25
Sintered Glass |
1960-002 |
1 |
| 25 |
Stainless Steel Support 25 mL
FG 25S 304 Stainless Steel 100 Mesh Screen |
1960-052 |
1 |
| 47 |
Glass Support 300 mL–FG 47
Sintered Glass |
1960-004 |
1 |
| 47 |
Stainless Steel Support 300 mL
FG 47S 304 Stainless Steel 100 Mesh Screen |
1960-054 |
1 |
| 90 |
Glass Support 1000 mL–FG 90
Sintered Glass |
1960-009 |
1 |
|
Hardware/Replacement Parts |
| |
Stopper, adapts 25 mm funnel to
manifolds, No. 8B |
1960-500 |
1 |
| |
Glass reservoir for FG47 (300
mL) |
1961-054 |
1 |
| Accessories |
| 10 |
Polyester Drain Disc |
230300 |
100 |
| 22 |
Polyester Drain Disc |
230500 |
100 |
| 25 |
Polyester Drain Disc |
230600 |
100 |
| 37 |
Polyester Drain Disc |
230800 |
100 |
| 47 |
Polyester Drain Disc |
231100 |
100 |
Note: 25 mm holders have No. 5 stopper, fitting 125 mL flasks;
47 mm and 90 mm holders have No. 8 stoppers, fitting standard
manifolds and 1 L flasks.
Syringe Type Holders S/S
Luer lock fittings connect to a standard syringe and offer
convenience and ease of use for clarification, sterilization and
removal of particulates from small volumes of liquid (e.g., HPLC
samples and solvents). PTFE gaskets and O-ring permit
autoclaving of the membrane in place without the filter sticking
to the holder.
 |
 |
 |
|
> Plastic Filtration Holders |
 |
Plastic Filtration Holders
Pop-Top™ and Swin-Lok™ Plastic Filter
Holders
Features and Benefits
- Designed for microfiltration and ultra
cleaning of small volumes of liquids using positive pressure
- All three holders will accommodate
Nuclepore track-etched and cast membranes
- Syringe compatible
| Typical Data |
| Materials |
13 mm Pop-Top |
25 mm Swin-Lok |
47 mm Swin-Lok |
| Holder |
Polycarbonate |
Polypropylene |
Polycarbonate |
| Maximum Operating Temperature
and Pressure |
38°C (100°F) at 50
psi (3.5 bar) |
| Sterilization |
121°C (250°F) for
15 minutes |
| Size (cm) |
2.7 OD x 2.7 H |
3.5 OD x 3.7 H |
6.0 OD x 6.5 H |
| Membrane Size (mm) |
13 |
25 |
47 |
| Prefilter Size (mm) |
10 |
22 |
42 |
| Filtration Area (cm2) |
0.8 |
3.9 |
13.8 |
| Connection |
| Cap |
Male luer slip-fit |
Female luer-lok |
Female luer slip-fit with Male
1/4" NPT and 1/4" Tubing (multi purpose) |
| Base |
Female luer slip-fit |
Male luer slip-fit |
|
| Ordering Information
- Syringe Type Holders S/S |
| Filter Diameter (mm) |
Description |
Catalogue Number |
Model |
Prefilter Diameter (mm) |
| 13 |
S/S, female luer inlet; male
luer nozzle outlet |
1980-001 |
SH13 |
10 |
| 25 |
S/S, female luer inlet; male
luer nozzle outlet |
1980-002 |
SH25 |
22 |
| Ordering Information
- Plastic Filtration Holders |
| Catalogue Number |
Description |
Diameter (mm) |
Quantity/Pack |
| 420100 |
Pop-Top |
13 |
10 |
| 420200 |
Swin-Lok Holder |
25 |
10 |
| 420400 |
Swin-Lok Holder |
47 |
10 |
|
|
|
Membrane prefilters
The life of a membrane filter can be extended many times by
placing a prefilter adjacent to or upstream of the membrane. The
total particulate load challenging the membrane is considerably
reduced thus allowing the membrane to operate efficiently.
Whatman manufacturers glass microfibres which are used as
prefilters for membranes. The unique properties of borosilicate
glass microfibres enable Whatman to manufacture filters with
high loading capacity and retention of very fine particulates.
The Whatman Multigrade GMF 150, used as a prefilter, nearly
doubles the volume of sample filtered compared to a single
density prefilter. Compared to an unprotected membrane, the
volume of sample filtered is three to seven times greater.
Conventional prefilters cannot perform up to the same calibre as
the Multigrade GMF 150 simply because prefilters of a uniform
density do not have the loading capacity of the new
multiporosity filter technology advanced by Whatman.
| Ordering Information
- Glass Microfiber Prefilters |
| Prefilter Diameter - (mm) |
Membrane Diameter - (mm) |
Catalogue Number - Grade GF/B
(fine) |
Catalogue Number - Grade GF/D
(coarse) |
- Quantity/Pack |
| 10 |
13 |
— |
1823-010 |
100 |
| 16 |
25 |
— |
1823-016 |
100 |
| 25 |
25 |
1821-025 |
1823-025 |
100 |
| 35 |
47 |
— |
1823-035 |
100 |
| 37 |
47 |
1821-037 |
— |
100 |
| 42.5 |
47 |
1821-042 |
1823-042 |
100 |
| 47 |
47 |
1821-047 |
1823-047 |
100 |
| 90 |
90 |
1821-090 |
1823-090 |
25 |
| 125 |
142 |
1821-125 |
1823-125 |
25 |
| 142 |
142 |
— |
1823-142 |
25 |
| 257 |
293 |
— |
1823-257 |
25 |
| - GMF 150 |
Catalogue Number - 10 µm/1 µm
|
Catalogue Number -
10 µm/2 µm |
| 47 |
47 |
1841-047 |
1842-047 |
40 |
| 90 |
90 |
1841-090 |
1842-090 |
40 |
|
|
|