Minifold I system

Minifold II system

TurboBlotter

Minifold® I system
Superior 96- and 48-well manifolds for proteins & nucleic acids
Dot-, Spot- and Slot-Blot Array Systems
The Minifold I system consists of four basic components: sample well plate, filter support plate, vacuum plenum, and metal clamping plate. The sample well plate is available in three configurations for producing spots, dots, or slots.

 

Blotting devices

The Minifold I system is compatible with multichannel pipettes. All three plates are interchangeable and can be purchased as an accessory plate in conjunction with a complete system. The tension on the clamping is adjustable, permitting use of a variety of blotting and filtration media.
 

 

Blotting devices
> 96-Well dot-Blot Plate

Minifold I Dot-Blot System - 96-Well

Unique O-ring design - ensures discrete dot formation without leakage of samples by cross lateral flow.

Generates even, uniform dots which eliminates uneven test areas resulting from manual sample application.

Two materials available - standard acrylic or autoclavable Delrin® .
 

 

Blotting devices
> 96-Well Spot-Blot Plate

Minifold I Spot-Blot System - 96-Well

Small volume required - sample volumes as low as 25 µL can be applied using less of your precious sample.

Very high signal intensity - 2 mm2 sample application area results in increased signal intensity.

Standard microtitration format- 96 samples on a single membrane; same as the standard Minifold Dot-Blot system.
 

 

Blotting devices
> 48-Well Spot-Blot Plate

Minifold I Slot-Blot System - 48-Well

Preferred format for densitometric scanning - slots can be easily quantitated.

Concentrated signal - 6 mm2 sample application area results in high signal intensity.

Easy to survey format - 48 samples on your membrane are easier to view than 96 samples.
 

 

Specifications - Blotting Devices
  Material Filter Area Max Capacity Pressure
96-Well Dot-Blot Plate Acrylic or Delrin® 12.5 mm2/dot 500 µL/well, 96 wells 0.9 bar, vacuum
96-Well Spot-Blot Plate Acrylic 2 mm2/spot (1x2 mm) 200 µL/well, 96 wells 0.9 bar, vacuum
48-Well Slot-Blot Plate Acrylic 6.24 mm2/slot (7.8x0.8mm) 1000 µL/well, 48 wells 0.9 bar, vacuum

 

Ordering Information - Minifold® I
Description Quantity/Pack Catalogue Number
Complete Systems
Minifold I Spot-Blot* System, complete 96-Well (Acylic) 1 10 447 850
Minifold I Dot-Blot* System, complete 96-Well (Acrylic) 1 10 447 900
Minifold I Slot-Blot* System, complete 48-Well (Acrylic) 1 10 447 941
Minifold I Dot-Blot* System, complete 96-Well (Delrin) 1 10 447 910
Replacement Parts
Minifold I Spot-Blot plate 1 10 447 852
Minifold I Slot-Blot plate 1 10 447 906
Minifold I Dot-Blot plate 1 10 447 905
Minifold I Clamping plate 1 10 447 960
Filter Support plate 1 10 447 903
Vacuum Plenum 1 10 447 968
O-rings 50 10 447 902
Accessory Products
Incubation plate 1 10 447 909
Cutting template 1 10 447 901
Membranes - 10.2 x 13.3 cm to fit Minifold I Systems
Protran®, BA79 0.1 µm 10 10 402 088
Protran, BA83 0.2 µm 10 10 402 488
Protran, BA85 0.45 µm 10 10 402 588
Optitran®, BA-S83 0.2 µm 10 10 439 388
Optitran, BA-S85 0.45 µm 10 10 439 188
Nytran® N, 0.45 µm 10 10 416 188
Nytran SuPerCharge, 0.45 µm 10 10 416 288
 
GB003 Blotting Paper 100 10 427 824
*Complete systems include: manifold apparatus, 5 sheets of Protran NC, 5 sheets of precut 3MM paper.

 

Delrin is a registered trademark of DuPont

 

Minifold® II system
 

 

Blotting devices

72-Well Slot-Blot Array System
The Minifold II system is designed for precise quantitative solid-phase assays with three rows of 24 slots, spaced according to multi-tip pipette format. The smaller slot surface area results in higher signal intensity and requires less sample than standard dot-blot formats. The resulting blot can be read with a densitometer.

 

 

Features and Benefits
 

  • Higher signal intensity - smaller slot surface area results in increased signal
  • Less sample - small slot dimensions require less sample than dot-blotters
  • Faster results - more intense signal generated with the slot-blotter allows to visualize results in less time
  • Accepts all types of transfer membranes - allows for choice of membrane with the highest binding capacity
  • Easy to assemble - beveled side rails assure rapid and accurate assembly

 

 

Specifications - Minifold® II System
Material Membrane Size Filter Area Capacity Pressure
Acrylic 6.3 cm x 22.8 cm 6.0 mm˛/well (0.75 mm x 8.0 mm slots) 600 µL/slot 0.9 bar, vacuum

 

Ordering Information - Minifold® II Slot-Blot System
Description Quantity/Pack Catalogue Number
Minifold® II Slot-Blot System, Complete* 1 10 447 800
Replacement Parts
Sample Well plate 1 10 447 801
Vacuum filter support w/ 1/4-inch vacuum tube adapter 1 10 447 864
Silicone O-Ring 1 10 447 813
Silicone Sheet 5 10 447 805
Vacuum Connector - 10 447 866
Membranes and Blotting Paper - 6.3 x 22.8 cm to fit Minifold II System
Protran® BA79, 0.1 µm 10 10 402 093
Protran® BA83, 0.2 µm 10 10 402 493
Protran® BA85, 0.45 µm 10 10 402 593
Nytran® SPC, 0.45 µm 10 10 416 293

* Complete system includes manifold apparatus, five sheets of pre-cut Protran BA85 nitrocellulose and five sheets of pre-cut 3MM paper.  

 

TurboBlotter™
Rapid Downward Transfer System
The TurboBlotter system is a rapid downward blotting device for high-resolution transfer of DNA and RNA.
 

 

Blotting devices
Blotting devices

The conventional Southern transfer stack has been turned upside down in order to take advantage of gravity. No heavy weights are required on the top of the transfer stack, eliminating the messy setup of standard upward capillary transfers.

The TurboBlotter system offers greater speed, target resolution and convenience versus traditional blotting procedures. Alkaline DNA transfers can be performed in as little as one hour, while neutral (SSC) transfers of DNA and RNA take only three hours.

Features and Benefits
 

  • Rapid - unique downward capillary transfer allows for alkaline buffer transfers in one hour and neutral (SSC) transfers in three hours.
  • Economical - reusable blotting device requires less buffer and blotting paper. Convenient refill packs available.
  • Compact - has a smaller footprint than most homemade devices and is stackable. Up to 5 units can be stacked on top of each other during transfers.
  • Easy to use - very easy to set up, and works without power or vacuum source

 

Each TurboBlotter system contains a transfer device, as well as the blotting paper and membranes for five transfers. The refill packs contain the blotting paper and membranes for five transfers.

 

Ordering Information - TurboBlotter™ System
The TurboBlotter systems below each include one 12 x 16 cm transfer device which can
accommodate gel sizes from 7 x 8 cm to 11 x 14 cm.
Description Size Catalogue Number
Nytran® SuPerCharge TurboBlotter Kits* 7 x 10 cm 10 416 328
  9 x 11 cm 10 416 336
  10 x 15 cm 10 416 300
  11 x 14 cm 10 416 304
Nytran® SuPerCharge TurboBlotter Refill** 7 x 10 cm 10 416 330
  9 x 11 cm 10 416 338
  10 x 15 cm 10 416 302
  11 x 14 cm 10 416 306
The TurboBlotter systems below each include one 21 x 26 cm transfer device which can
accommodate gel sizes from 12 x 21 cm to 20 x 25 cm.
Nytran® SuPerCharge TurboBlotter Kits* 12 x 21 cm 10 416 308
  15 x 15 cm 10 416 312
  15 x 20 cm 10 416 316
  20 x 20 cm 10 416 320
  20 x 25 cm 10 416 324
Nytran® SuPerCharge TurboBlotter Refills** 12 x 21 cm 10 416 310
  15 x 15 cm 10 416 314
  15 x 20 cm 10 416 318
  20 x 20 cm 10 416 322
  20 x 25 cm 10 416 326
*Each TurboBlotter Kit includes: transfer device, 5 sheets of membrane, 40 sheets of 3MM, 100 sheets of GB004,
and 5 wicks of GB002.
**TurboBlotter Refills include: 5 sheets of membrane, 40 sheets of 3MM, 100 sheets of GB004, and 5 wicks of GB002.
 

 

 

 

 

 

For more information :: Bioxys and Gentaur BVBA :: Av. de l'Armée 68 B4 :: BE-1040 BELGIUM

Email: info@gentaur.com
 

International 

+32 (0) 16 58 90 45

+32 (0) 16 50 90 45

France

01 43 25 01 50

01 43 25 01 60

Italy

02 36 00 65 93

02 36 00 65 94

Germany

0241 6085 13140

0241 6085 33033

Send mail to webmaster with questions or comments about this web site.
Copyright © 2005 Gentaur BVBA
Last modified: feb-07