Application Specific Plates
384 Well DNA binding UNIFILTER®
Dye_terminator_removal_UNIFILTER®_96_well_and_384_well
ELISA_UNIFILTER®
High_throughput_genomics_UNIFILTER®
PCR_cleanup_UNIFILTER®
Phase_separation_UNIFILTER®
Protein_kinase_assay_UNIFILTER®
Protein_precipitation_UNIFILTER®_FF
96_Well_bacterial_growth_plate
96_Well_DNA_binding_UNIFILTER®
96_Well_lysate_clarification_UNIFILTER®
Plasmid_miniprep
|
 |
 |
 |
|
> 384 Well DNA
binding UNIFILTER |
 |
384 Well DNA binding
UNIFILTER®
The 384 Well DNA Binding UNIFILTER plate effectively binds and
purifies DNA molecules. It provides highly reproducible results
with yields exceeding 2 µg/well, from bind-wash-elute processing
with collection by filtration. Minimal liquid hang up allows for
reduced elution volume, enabling DNA concentration as high as
150 ng/µL. Further ethanol precipitation is unnecessary. The DNA
is ready to use.
Features and Benefits
- High efficiency bind-wash-elute processing with
collection by filtration
- simplifies automation with no cross contamination
- Highly reproducible results yielding DNA purity
exceeding 2µg per well sufficient for sensitive downstream
applications
- Minimal liquid hang up allows for reduced elution volume
with DNA concentration as high as 150ng/µL
| Ordering Information
- 384 Well DNA Binding UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume (µL) |
Plate Material |
Filter Media |
Quantity/Case |
| 7700-2110 |
384 |
100 |
Clear Polystyrene |
DNA Binding |
50 |
| 7701-1100 |
384 |
100 |
Clear Polystyrene |
N/A |
50 |
|
|
| |
 |
 |
 |
| > Dye terminator
removal UNIFILTER |
 |
Dye
terminator removal UNIFILTER® 96 well and 384 well
The Whatman Dye Terminator Removal plates are available in 96 wells and
384 well formats. These plates can be used with gel filtration media for
high throughput sequencing reaction cleanup, including removal of dye
blobs.
They are constructed from rigid polystyrene that can withstand
centrifugation. Laboratory packing of gel filtration media is less
expensive than pre-packed plates or spin columns.
| Ordering Information - 96
Well Dye Terminator Removal UNIFILTER® |
| Catalog Number |
Well Format |
Well Volume (µL) |
Plate Material |
Well Bottom |
Quantity/Case |
| 7700-2801 |
96 |
800 |
Polystyrene |
Filter, LDD* |
25 |
| 7701-5750 |
96 |
750 |
Natural Polypropylene |
Round |
25 |
| 384 Well Dye Terminator
Removal UNFILTER®
|
| Catalog Number |
Well Format |
Well Volume (µL) |
Plate Material |
Well Bottom |
Quantity/Case |
| 7700-1101 |
384 |
100 |
Polystyrene |
Filter, LDD* |
50 |
|
| |
ELISA UNIFILTER®
The Whatman ELISA plate allows researchers to use the binding
characteristics of nitrocellulose in the standard SBS 8 x 12 multiwell
format. It is also suitable for other types of ligand binding
applications such as hybridoma supernatant screening. Solutions are
easily vacuumed to waste using a vacuum manifold.
Chemiluminescent assays can be read in the plate. If the ELISA
product is eluted then centrifugation is preferred. This microplate is
compatible with automated systems.
| Ordering Information - ELISA
UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume |
Plate Material |
Filter Media |
Well Bottom |
Quantity/Case |
| 7700-3307 |
96 |
350 µL |
White Polystyrene |
0.45µm CN * |
Filter |
50 |
| 7701-1350 |
96 |
300 µL |
Clear Polystyrene |
N/A |
Flat |
50 |
| 7701-5200 |
96 |
2 mL |
Natural Polypropylene |
N/A |
Round |
25 |
| 7705-0107 |
UniVac™ Vacuum to Collect
Manifold, acrylic |
1 |
| 7704-0001 |
Clear Polyester ThinCold
Sealing Film Adhesive Backing |
100 |
| * CN = Cellulose nitrate |
|
| |
 |
 |
 |
| > High throughput
genomics UNIFILTER |
 |
High throughput genomics UNIFILTER®
With ever increasing demand for simple, fast methods to purify DNA from
bacterial cultures, the Whatman Genomics microplate is the ideal
solution for the clarification of lysates containing large insert
vectors.
This microplate has a Cellulose Acetate membrane with a special
support, which clears nonchaotropic bacterial lysates, and long drip
directors. Without further purification, the DNA is clean enough for
further enzymatic manipulation. Cellulose Acetate acts as both a depth
filter and a fine particle filter. The 0.45 µm pores do not block
because of the depth effect of the membrane. Cellulose Acetate is also
inert and does not bind either DNA or protein.
| Ordering Information - High
Throughput Genomics UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume |
Plate Material |
Filter Media |
Well Bottom |
Quantity/Case |
| 7700-2808 |
96 |
800 µL |
Clear Polystyrene |
0.45 µm CA* |
N/A |
25 |
| 7701-5205 |
96 |
2 mL |
Natural Polypropylene |
N/A |
Round |
25 |
| 7701-5200 |
96 |
2 mL |
Natural Polypropylene |
N/A |
Round |
25 |
| 7701-5750 |
96 |
750 µL |
Natural Polypropylene |
N/A |
Round |
25 |
| * CA = Cellulose acetate |
|
| |
PCR cleanup
UNIFILTER®
Process 96 or 384 samples quickly with greater than 85% recovery. The
Whatman PCR Cleanup UNIFILTER eliminates time-consuming precipitations
and labour-intensive resin purifications. Purified DNA is ready for
sequencing, hybridization assays and microarrays.
The PCR Cleanup UNIFILTER can be used with both vacuum and centrifuge
techniques. (Centrifugation is recommended for final elution with the
384 well UNIFILTER.)
| Ordering Information - PCR
Cleanup UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume (µL) |
Plate Material |
Filter Media |
Quantity/Case |
| 7700-2810 |
96 |
800 |
Clear Polystyrene |
DNA Binding |
25 |
| 7701-5250* |
96 |
250 |
Natural Polypropylene |
N/A |
50 |
| 7700-2110 |
384 |
100 |
Clear Polystyrene |
DNA Binding |
50 |
| 7701-1100 |
384 |
100 |
Clear Polystyrene |
N/A |
50 |
| * Does not comply with SBS Standards. |
|
| |
Phase
separation UNIFILTER®
The Whatman Phase Separation Plate allows for a quick separation of
halogenated solvents from an aqueous phase, with no carryover and no
close manual contact. The plate consists of a 2 mL, 96 well, rigid
glass-filled polypropylene body. It has long drip directors to ensure
accurate dispensing of the filtrate. Whatman 1PS media is sealed into
each well.
Whatman 1PS is a silicone-treated medium which remains impervious to
aqueous solvents but allows the unimpeded passage of organic solvents.
Providing that the solvent layer is in contact with the 1PS, the organic
solvent layer will drain under gravity until the aqueous interface is
reached, when flow will stop automatically. If subsequent harvesting of
the aqueous layer is required, a vacuum can then be applied to remove
this layer.
| Ordering Information - Phase
Separation UNIFILTER® |
| Catalog Number |
Well Format |
Well Volume |
Plate Material |
Well Bottom |
Quantity/Case |
| 7720-7229-01 |
96 |
2 mL |
Glass Filled Polypropylene |
Phase Separation |
1 |
| 7701-5750 |
96 |
750 µL |
Natural Polypropylene |
Round Bottom |
25 |
| 7701-5200 |
96 |
2 mL |
Natural Polypropylene |
Round Bottom |
25 |
|
| |
 |
 |
 |
| > Protein kinase assay
UNIFILTER |
 |
Protein kinase assay UNIFILTER®
The Whatman Protein Kinase Assay filter plate incorporates a P-81 filter
in each well. P-81 is a cation exchanger that binds peptides but does
not bind unincorporated ATP, resulting in low non-specific background
noise and high sensitivity in kinase assay.
The filter plate is produced to SBS standards in rigid white
polystyrene or Barex to eliminate optical crosstalk problems during
Liquid Scintillation Counting. The 150 µL UNIFILTER has shallow wells
enabling higher detection sensitivity.
| Ordering Information -
Protein Kinase Assay UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume (µL) |
Plate Material |
Filter Media |
Well Bottom |
Drip Director |
Quantity/Case |
| 7700-3312 |
96 |
350 |
White Polystyrene |
Whatman P 81 |
Filter |
Short |
50 |
| 7700-4312 |
96 |
350 |
White Polystyrene |
Whatman P 81 |
Mesh |
Mesh |
50 |
| 7700-0512 |
96 |
150 |
White Barex |
Whatman P 81 |
Mesh |
Mesh |
50 |
| 7705-0101 |
96 |
N/A |
Polyurethane |
N/A |
— |
— |
1 |
|
| |
 |
 |
 |
| > Protein precipitation
UNIFILTER FF |
 |
Protein precipitation UNIFILTER® FF
The Whatman Protein Precipitation UNIFILTER FF (Fast Flow)is optimized
for removing acetonitrile-precipitated proteins from plasma or serum
samples. Made with 2 mL, 96 well, rigid glass-filled polypropylene
microplates, the Whatman Protein Precipitation UNIFILTER is both robust
and chemically resistant.
The plates contain specially formulated dual membranes with two
distinct layers. The top layer acts as a prefilter to remove coarse
particulates. The bottom layer is oleophobic for retaining the well
contents without dripping. This provides a final filter for removing
fine particulate matter when a vacuum is applied. The plates are
available in the following well bottom formats: Standard; Fast Flow;
Round Bottom and "V" Bottom.
Features and Benefits
- 96 samples purified at the same time
- Purified samples available in less than 10 minutes
- Precipitation and filtration in the same well
- No laborious pipetting and/or centrifugation required and
minimal liquid handling
- Dual Whatman filter media
- Ensures no fluid loss during incubation and fast flow during
filtration
- Over 98% protein removal
- Sample volumes up to 150µL for plasma and 200µL for serum
- SBS compatible with the exception of the "V" bottom plate
- Robotics friendly
| Ordering Information -
Protein Precipitation UNIFILTER® FF |
| Catalogue Number |
Well Format |
Well Volume |
Plate Material |
Well Bottom |
Quantity/Case |
| 7720-7235 |
96 |
2 mL |
Glass Polypropylene |
Standard |
1 |
| 7720-7236 |
96 |
2 mL |
Glass Polypropylene |
Fast Flow |
5 |
| 7701-5750 |
96 |
750 µL |
Natural Polypropylene |
Round Bottom |
25 |
| 7701-5200 |
96 |
2 mL |
Natural Polypropylene |
Round Bottom |
25 |
|
| |
 |
 |
 |
| > 96 Well bacterial
growth plate |
 |
96
Well bacterial growth plate
The Whatman High Throughput Bacterial Growth plate can simplify and
accelerate the growth of 96 individual 1.5 mL bacterial cultures. It is
used for both overnight cultivation and the initial "spin down" of
bacteria. Made of medical grade polypropylene with a clear polystyrene
lid, this gamma-irradiated plate eliminates the need to grow multiple,
discrete cultures. It also optimises space and efficiency in the
incubator.
Whatman has demonstrated that culture integrity is not affected by
the close proximity of neighbouring cultures and that each culture grows
to the same density as it would in individual culture tubes (at 325 rpm
and 37°C for 16 hours).
Features and Benefits
- Consistent cell densities across all 96 wells
- Eliminates cross contamination between wells
- Growth comparable to individual test tubes
- Ability to automate allows for increased productivity
| Ordering Information - 96
Well Bacterial Growth Plate |
| Catalogue Number |
Well Format |
Well Volume (mL) |
Plate Material |
Irradiated with Lid |
Quantity/Case |
| 7701-5205 |
96 |
2 |
Polypropylene |
Yes |
25 (individually bagged) |
|
| |
 |
 |
 |
| > 96 Well DNA binding
UNIFILTER |
 |
96
Well DNA binding UNIFILTER®
Whatman Plasmid DNA Binding UNIFILTER works either as a stand-alone or
as part of our high throughput miniprep system.
Plasmid DNA is bound to the filter under chaotropic conditions,
washed twice and then vacuumed to dryness on a vacuum manifold. The
plasmid DNA is eluted by vacuum in a final volume of 100 µL into a
nonbinding polypropylene collection plate using water or TE-1 Buffer.
The DNA is ready to use and further ethanol precipitation is
unnecessary. The final concentration is 50 to 100 ng/µL, depending on
the original culture. The OD260/280 ratio is 1.9 and the yields in all
96 wells "max out" at 6 µg. Full protocol is available on request.
The Plasmid DNA Binding plate can be used with both vacuum and
centrifuge techniques, making it a vital and flexible tool in every high
throughput lab.
Features and Benefits
- DNA recovery of 6µg per well on average
- Consistent yield across all 96 wells
- Eluted plasmid DNA is free of genomic DNA contamination
- High quality DNA suitable for PCR, restriction digestion and
sequencing
- Save time, no desalting or ethanol precipitation
- No kit required, significantly reduces costs
| Ordering Information - 96
Well DNA Binding UNIFILTER® |
| Catalog Number |
Well Format |
Well Volume (µL) |
Plate Material |
Filter Media |
Quantity/Case |
| 7700-2810 |
96 |
800 |
Clear Polystyrene |
DNA Binding |
25 |
|
| |
 |
 |
 |
| > 96 Well lysate
clarification UNIFILTER |
 |
96 Well lysate
clarification UNIFILTER®
The Whatman Lysate Clarification UNIFILTER can utilize either vacuum or
a centrifuge. The vacuum process is significantly easier to automate
with consistency across all wells. It also has an average DNA recovery
rate 10 to 30% higher than the manual centrifuge method. This method
filters out cell debris to obtain plasmid DNA in the aqueous phase.
Whatman filter technology results in high particle retention and fast
flow rates while producing a clean lysate. The Lysate Clarification
plate is an important tool for high throughput plasmid DNA purification.
Features and Benefits
- Process 96 lysates in less than 10 minutes
- DNA recovery of 6µg per well on average
- Increase DNA recovery by 10 to 30%
- Consistent yield across all 96 wells
- User flexibility of using either centrifugation or vacuum
- 96 well format is easily automated
| Ordering Information - 96
Well Lysate Clarification UNIFILTER® |
| Catalogue Number |
Well Format |
Well Volume (µL) |
Plate Material |
Filter Media |
Quantity/Case |
| 7720-2830 |
96 |
800 |
Clear Polystyrene |
Lysate Clarification |
25 |
|
| |
Plasmid miniprep
The preparation of plasmid DNA from bacterial culture is an extremely
common procedure. The Whatman Plasmid Miniprep System simplifies the
process, increases the throughput and improves the purity of plasmid
DNA.
The Whatman Plasmid Miniprep System consists of a few basic steps,
each with an optimized microplate.
| Average Yield Per Well |
6.0 µg |
| A260/A280 |
1.94 |
| EcoR1 Digest |
Yes |
| Sequencing Accuracy (BLAST) |
97% over 600 bp |
Full protocol available on request.
| Ordering Information -
Plasmid Miniprep |
| Catalog Number |
Well Format |
Well Volume |
Plate Material |
Well Bottom |
Filter Media |
Irradiated with Lid |
Quantity/ Case |
| 7701-5205 |
96 |
2 mL |
Natural Polypropylene |
Round |
— |
Yes |
25 |
| 7720-2830 |
96 |
800 µL |
Clear Polystyrene |
Filter, LDD† |
Lysate Clarification |
No |
25 |
| 7700-2810 |
96 |
800 µL |
Clear Polystyrene |
Filter, LDD† |
DNA Binding |
No |
25 |
| 7701-5200* |
96 |
2 mL |
Natural Polypropylene |
Round |
— |
No |
25 |
| 7701-5750* |
96 |
750 µL |
Natural Polypropylene |
Round |
— |
No |
25 |
| 7701-5250** |
96* |
250 µL |
Natural Polypropylene |
“V” |
— |
No |
50 |
| Catalog Number |
Description |
Quantity/ Case |
| 7705-0102 |
UniVac™ 3 vacuum/collect
manifold |
1 |
| * Collection plates |
| ** Does not comply with SBS Standards. |
| † LDD = Long Drip Director |
|
|