Description:
 |
GeBAflex-tube buffer exchange defines
the next dialysis generation technology. Based on a single-use
tube, single step, volume ranging from:
Mini GeBAflex-tube , for
volume range 10µl to 250µl
Midi GeBAflex-tube , for
volume range 50µl to 800µl
Maxi GeBAflex-tube , for
volume range 100µl- 3000µl
MeGa GeBaFLEX-tube, for volume
range 0,5ml - 20ml
By changing the GeBAflex-tube
Maxi cap (two caps are provided with the kit) one can easily
adjust the dialysis volume between 100-2000 and 100-3000µl.
Loading and unloading of samples is secure and most convenient
dialysis tool in the market.
|

|
Midi GeBAflex-tube
Vol. 50-800µl |
|
Catalog |
MWCO |
Unit |
Product |
|
DO10 |
3500 |
10 |
GeBAflex-tube |
|
DO12 |
3500 |
30 |
|
|
DO20 |
6000-8000 |
10 |
|
|
DO22 |
6000-8000 |
30 |
|
|
Maxi GeBAflex-tube Vol. 100-3000µl |
|
Catalog |
MWCO |
Unit |
Product |
|
DO30 |
3500 |
5 |
GeBAflex-tube |
|
DO35 |
3500 |
15 |
|
|
DO40 |
6000-8000 |
5 |
|
|
DO45 |
6000-8000 |
15 |
|
|
DO50 |
12000-14000 |
5 |
|
|
DO55 |
12000-14000 |
15 |
|
APPLICATIONS:
- Buffer exchange.
- Removal of ethidium bromide from
nucleic acid samples.
- Minimum Dialysis sample size: 10
µl.
- Removal of urea.
- Removal of detergents.
Mini / Midi
/ Maxi GeBAflex-tube dialysis kit contents:
GeBAflex-tubes:
5/10/15/30, Floating rack, Handbook.
SPECIFICATIONS:
Liquid
sample recovery 97%
- Mini GeBAflex-tube:
Volume range: 10- 250µl
- Midi GeBAflex-tube:
Volume range: 50-800µl
- Maxi GeBAflex-tube:Volume
range: 100-3000µl
Membrane MWCO: 3500, 6000-8000 and 12000-14000 Da.
Purity: No contamination with Protease, RNase, DNase
and PCR product free.
Membrane treatmnet: ultra-clean, sulfur and heavy metal
free and EDTA treated.
Single use unit, no need for cleaning or autoclave.
Single step process.
Dialysis with
GeBAflex-tube:
 |
Ability of
GeBAflex-tube to dialyze samples volume. 100, 80, 50 or 30 µl of
10 U of PstI restriction enzyme in buffer 0+ (100%
activity) containing 8M urea (0% activity) was subject for
dialysis for 4 hours by GeBAflex-tube against 2 liters buffer 0+
without urea. The solution was transfered to a clean
microcentrifuge tube and 1 µg of pBS plasmide was added, the
digestion proceed for 8 hours at 37oC. A-D controls,
A, digestion of pBS with PstI in buffer 0+ containing 8M urea,
B, digestion of pBS with PstI in buffer 0+, C,
digestion of pBS with PstI in buffer taken from the beaker in
the end of the dialysis, D, un-cut pBS.
|
DIALYSIS PROCESS Volume
range: 10µ to 20ml
MeGAflex-tube dialysis
volume range :
minimum 1ml , step 10ml, 15ml
step, 20ml l, 10ml, 15ml, 20ml

s
lex-tubes

Mini floating pad support
up-to 4 Midi GeBAflex-tubes + 9 Mini GeBAflex-tubes |